VMware converter states "The source parameters are invalid"
I am using version 6.0.0 build 2716716 of the VMware vcenter Converter Standalone client. I am trying to convert a Storagecraft Shadowprotect (build version v5.2.0.36537) image of a desktop computer...
View ArticleRe: VMware converter states "The source parameters are invalid"
Converter 6.0 User's guide (https://www.vmware.com/pdf/convsa_60_guide.pdf), on page 22, supported sources table: * StorageCraft ShadowProtect Desktop, ShadowProtect Server, ShadowProtect Small...
View ArticleRe: P2V conversion stop at 97 %
I try to boot up the VM , but it is stuck in blue screen with error 0x0000007b.Any other alternative way for me to make this VM up since my data has been completed clone? I have again convert and now...
View ArticleRe: P2V conversion stop at 97 %
Hello A few comments: - The interesting log is the agent's one. It is located on the source machine (same folder path as worker's). - Have you tried to just reconfigure the destination machine? If not...
View ArticleRe: A general system error occurred platform-specific error 38
I was able to determine the problem was with the install of VMware converter on the OS. I ended up uninstalling VMware converter and then searching the registry for all references of VMware, removing...
View ArticleRe: P2V conversion stop at 97 %
Hi Plamen, I have attached again the agent log. 1) I have tried to repair but failed due to the OS does't have the option to repair.2) i have try to reconfigure the VM but it also failed and give me...
View ArticleRe: P2V conversion stop at 97 %
Hi again Zack It was a mistake to ask for the agent's logs, sorry for that (I thought converter was installed on a separate machine).On more careful examination, the worker log...
View ArticleVmacore::TimeoutException(Operation timed out)
I am trying to convert a Windows 7 machine with 4GB into a VM using VMware vCenter Converter standalone.I keep on getting following internal error:Error vmware-converter-worker[05796] [Originator@6876...
View ArticleRe: Vmacore::TimeoutException(Operation timed out)
How are you trying to convert ? Remote or on the machine ? Which version , try to download the latest version of standalone converter Try to install the converter on the 2008 R2 server on which you...
View ArticleYet another P2V Conversion failure: unable to submit job:...
Hello I guess title says it all.... Trying to convert a Win7 machine to ESXi vCenter 5.5 - the job never gets to the point of starting as I get an error at submission. Tried both with converter 5.5.3...
View ArticleRe: Yet another P2V Conversion failure: unable to submit job:...
You have to make sure you have network connectivity on port 902 both from Converter Server machine and the source machine to the destination ESX server (note it is not the vCenter server). If your ESX...
View ArticleRe: Yet another P2V Conversion failure: unable to submit job:...
Thanks ! That was indeed my issues (connectivity to the ESX machine) - all ok now.All I wish is the the converter app could present us with a more helpful message (could not establish network connexion...
View ArticleVMWare Converter: (A file I/O error occurred while accesssing ". )
Hello, I am experiencing a problem with VMWare Converter. When trying to start the job, I get an error saying "A File I/O Error Occurred while accessing ". ". I am running it locally on the source...
View Articlep2v server 2012 r2 to vcenter 6
Is this currently supported? We run a 5.1 environment at the moment, but need to convert a customer in the future. I'd expect our new environment to be on 6.0. If not, do you know if there will be...
View ArticleRe: p2v server 2012 r2 to vcenter 6
Yes, it's supported, also you can use Converter 6.0HTH
View ArticleRe: VMWare Converter: (A file I/O error occurred while accesssing ". )
A File I/o Error Occurred While Accessing Vmware Converter and other critical errors can occur when your Windows operating system becomes corrupted. Opening programs will be slower and response times...
View ArticleRe: VMWare Converter: (A file I/O error occurred while accesssing ". )
Hm, just a wild guess, but can you try to connect to Converter Server using IP address instead of connecting to local server? I mean you would still connect to the local server, but through the network...
View Articlehost key fingerprint verification failed when converting a linux machine
I am using converter 6.0.0 to convert a physical linux machine to vm. I have getting the following error repeatedly. It always stopped at 3% after 3 minutes msg = "A general system error occurred: #...
View ArticleRe: host key fingerprint verification failed when converting a linux machine
Hello it is possible the helper VM can't resolve XYZ.mit.edu. You can try a ping from another VM in the same VM network to verify that.If that's the case, use the IP address of the source machine....
View ArticleRe: host key fingerprint verification failed when converting a linux machine
Hi Plamen, You are correct. The network of the helper VM was not configured properly. After I changed the network configuration, it passed the error. Thank you so much!
View Article